Print

Environmental & Test Instruments

Product Code Product Description
VAH 40–Laserdistance meter(MET071) Range. 0.05 m – 40 m,Meters/feet/inches,Continuous measurement,Area/Volume Summation
VAH 100–Laserdistance meter(MET072) Range. 0.05 m – 100m,Max/Min measurement,Area/Volume summation,Display illumination
VA 6530 – Infra-redthermometer(MET072) Range. -20C to 537 C,Distance : Spot ratio 12:1,Backlight, LCD display – 4 digit,Auto power off
VA 6520. Infra-red thermometer(MET076) VA 6520. Infra-Red Thermometer. Range: -50 to 500 C /Single dot laser target / Back light / Field of view 8:1 / Hold function
VA 8020 – Temp /Anemometer (MET077) Measures: m3 /s m3/hr,Temperature C / F (10 – 50C), Accuracy : 2%,Auto power off/ Data hold,Max / Min. Back light
VA 8080 –Soundlevel meter (MET079) 30 dB – 120 dB (Resolution 1 dB),Four ranges (30-60/50-80/70-100/90-120),Auto power off, Frequency: 31.5Hz – 8 KHz (A),Accuracy 1.5dB
VA 8030 – Tachometer) (MET081) Non –contact model,Range. 100 – 30000 rpm,Accuracy to 0.1 %,9 impeller settings,Auto power off ,Range. 0.0% - 95.7% / -10C - 50C
VA 8040 – Moisture meter (MET083) Cement/plaster produce,Hardwood/Soft wood ,Cement mortar/Lime mortar,Bricks
VA 8050 – Lux Meter(MET078) Range. 0-30000 Lux/0-2788 ftc,Resolution. 1 Lux/0.1 ftc,Double parameter.Lux (lm/m2),foot candle (lm/ft2),Sample rate. 1 time / second,Auto power off / low battery indicator
VA 8010 - Temperature Humiditymeter(MET082) Parameters.C / F/ % RH. / td(dew point temperature,Autopower off,Range. -10 C to + 50 C / 0 – 100% humidity, Resolution. 0.1 C / 0.1 F / 0.1% RH
VA 8042. Coating thickness gauge.(MET087) VA 8042. Coating Thickness Unit. Measurement of coating thickness of paint / plastic / enamel / chrome plating /copper plating on steel . 4 digit display / Range: 0-1200 um/ Accuracy 3%
VA 588 – Insulation multimeter(MET066) AC/DC true RMS measurement,Insulation resistance range. 50 KOhms – 10G Ohms,DC voltage.0.001 v – 1000v. AC 0.1mv – 1000v,DC current/ AC current,Resistance 0.1 – 50 MOhms,Frequency 5 Hz – 2 MHz
MS 5209 – Earth Resistance Tester(MET064) Earth resistance range. 10 / 100 / 1000 Ohms,Earth voltage. 30 v AC (50Kohms /V ),Earth resistance / Earth voltage. With 5% of full scale,Earth resistance measurement by current inverter,Earth voltage by rectifier ,Self-check facility
MS 5710 - Phase Tester(MET065) Voltage range. 100v – 480 v,Frequency response. 40 – 70 Hz,Test time 110 v –continuous / 220 v 3 min / 480 v – 4 min,Clip leads 1.2 m
MAS 830B – Digital multimeter(MET051) DC. 20mV – 600 v / AC. 200v – 600v,DC current. – 10A,Data hold / Diode test / Continuity buzzer /Transistor test,Back light,CAT 2 – 600v
MS 8201 – Digital multimeter(MET052) DC. 400mV – 1000 v / Current. 4000uA – 10A,AC. 4 v – 750 v / Current. 4000uA – 10 A,Resistance. 400 ohm – 40 MOhm,Frequency. 10 Hz – 1000 Khz,Diode test / Continuity buzzer/Auto ranging,CAT 3 – 600 v / CAT 2 – 1000 v
VA 19 – 5 in 1 Environmental Multimeter(MET054) DC voltage / current,Ac voltage / current,Frequency / Temperature / Humidity,Lux meter / decibel meter,Continuity test
M266 – Digital Clamp meter(MET061) DC voltage 2v – 1000 v,AC voltage. 200 v – 750 v / Current. 200A – 1000A,Resistance. 200 Ohm – 2 MOhm,Frequency / Diode test / Continuity buzzer test
VA 310. Digital Clamp meter(MET062) DC voltage. 2 v – 1000v,AC voltage. 2v – 750 v / Current. 20 A – 1000A,Resistance,Temperature/ Diode test / Back light,Data hold
VA 311. Digital AC/DC Clamp meter(MET063) DC voltage. 400mV – 1000v / Current. 400 A – 1000A,AC voltage, 4 v – 700v / Current. 400A – 1000A,Resistance / Frequency,Temperature,Diode test / Continuity buzzer/data hold